REL-MR-60DC/21AU
Product Type: Single relay, which belongs to the miniature power relay type, with plug-in connection, easy to install and maintain.
Electrical characteristics
Coil side: Rated input voltage is 60V DC and input voltage range is 36V DC to 165V DC. The drive mode is monostable and bipolar. At the rated input voltage, the typical input current is 3mA, the typical response time is 5ms, the typical release time is 2.5ms, the coil resistance is 20500Ω±15% at 20°C, and the power consumption is 0.18W under the specified conditions.
Contact side: 1 changeover contact type, single contact type for switching, contact material for AgSnO hard gold plating. Under normal conditions, the maximum switching voltage is 30V AC, 36V DC, the minimum switching voltage is 100mV (at 10mA), the limiting continuous current and start-up current are both 50mA, the minimum switching current is 1mA (at 24V), and the rated power value (resistive load) is 1.2W (24V DC). When the gold plating layer is destroyed, the maximum switching voltage is 250V AC, the minimum switching voltage is 5V (at 100mA), the limited continuous current is 6A, the minimum switching current is 10mA (at 12V), the rated power value (resistance load) will change accordingly, such as 140W (24V DC), 20W (48V DC), 18W (60V DC), etc., and the switching capacity is 2A (at 24V, DC13), 0.2A (at 110V, DC13), etc.
Electrical characteristics
Coil side: Rated input voltage is 60V DC and input voltage range is 36V DC to 165V DC. The drive mode is monostable and bipolar. At the rated input voltage, the typical input current is 3mA, the typical response time is 5ms, the typical release time is 2.5ms, the coil resistance is 20500Ω±15% at 20°C, and the power consumption is 0.18W under the specified conditions.
Contact side: 1 changeover contact type, single contact type for switching, contact material for AgSnO hard gold plating. Under normal conditions, the maximum switching voltage is 30V AC, 36V DC, the minimum switching voltage is 100mV (at 10mA), the limiting continuous current and start-up current are both 50mA, the minimum switching current is 1mA (at 24V), and the rated power value (resistive load) is 1.2W (24V DC). When the gold plating layer is destroyed, the maximum switching voltage is 250V AC, the minimum switching voltage is 5V (at 100mA), the limited continuous current is 6A, the minimum switching current is 10mA (at 12V), the rated power value (resistance load) will change accordingly, such as 140W (24V DC), 20W (48V DC), 18W (60V DC), etc., and the switching capacity is 2A (at 24V, DC13), 0.2A (at 110V, DC13), etc.